Gas
Station for API & LC/MS/MS Analysers from PEAK Scientific Instruments |
| Model |
Flow
Rate N2 |
Flow
Rate Air |
Outlet
Pressure |
Notes |
| NM20ZA |
Curtain
Gas (Nitrogen) 5L/min @ 60psi |
Source
Gas (Zero Air) 22L/min
@ 100psi Exhaust Gas (Air) 8L/min @ 60psi |
System
Set |
Designed for LC/MS API analysers
Mobile
Plug & use system
Three gas lines from 1 system
Safety cut out feature
Noise level 59 db(A) |
| A120DR |
90 l/min |
120 psi |
Meets API Purity Needs |
• Quiet in Operation
• Uninterrupted supply of compressed air
• Mobile
• Improved Reliability
• Integrated Self Diagnosis |
| N300DR |
12 L/min N2 - Curtain Gas
26 L/min Zero Air -
Source Gas
8 L/min Air -
Exhaust Gas |
60 psi
100 psi
60 psi |
Meets API Purity Needs |
• Integral - Oil Less
• Improved Reliability
• Integrated Self Diagnostics
• Mobile
• Quiet in Operation |
| A320DR |
12 L/min N2 Curtain gas
26 L/min (Zero Air) Source Gas
8 L/min (Air) Exhaust Gas |
60 psi
100 psi
60 psi |
Meets API Purity Needs |
• Dual redundancy compressor
• Continuous service |
| NM20Z |
Curtain
Gas (Nitrogen) 10L/min @ 60psi |
Source
Gas (Zero Air) 22L/min
@ 100psi Exhaust Gas (Air) 8L/min @ 60psi |
110
- 130 psi |
Configured for Positive Ion Mode of your API Analyser
Wall Mountable
Plug & use system
Three gas lines from 1 system
No electrical requirements |
| NM20ZL |
Curtain Gas (Nitrogen)
12L/min
Source Gas (Zero Air)
22L/min
Exhaust Gas (Air)
8L/min |
80 psi
110 psi
60 psi |
Meets API/MDS
Sciex Purity Needs |
• Dual redundant Air
Compressors
• Improved Reliability
• Integrated Self Diagnostics
• Mobile
• Quiet in Operation
• Connects to In House Air |
| NM40Z |
Curtain Gas (Nitrogen)
24L/min
Source Gas (Zero Air)
52L/min
Exhaust Gas (Air) 16L/min |
80 psi
110 psi
60 psi |
Meets API/MDS
Sciex Purity Needs |
• Connection for 2 API
LC/MS/MS Analysers
• Plug & use system
• Mobile |
| NM60Z |
Curtain Gas (Nitrogen)
36L/min
Source Gas (Zero Air)
78L/min
Exhaust Gas (Air) 24L/min |
80 psi
110 psi
60 psi |
Meets API/MDS
Sciex Purity Needs |
• Connection for 2 API
LC/MS/MS Analysers
• Plug & use system
• Mobile |
| NM80Z |
Curtain Gas (Nitrogen)
48L/min
Source Gas (Zero Air)
104L/min
Exhaust Gas (Air) 32L/min |
80 psi
110 psi
60 psi |
Meets API/MDS
Sciex Purity Needs |
• Connection for 2 API
LC/MS/MS Analysers
• Plug & use system
• Mobile |
| ABN2ZA |
Curtain Gas (Nitrogen)
12L/min
Source Gas (Zero Air)
24L/min
Exhaust Gas (Air) 8L/min |
80 psi
110 psi
60 psi |
System Set |
• Designed for API LC/MS
instruments
• 2 Independent air supplies
• Plug & use system
• Mobile
• Quite in operation |
| AB-3G |
Curtain Gas (Nitrogen)
12L/min
Source Gas (Zero Air)
24L/min
Exhaust Gas (Air) 8L/min |
@ 5.52 bar , 0.42 CFM
@ 80 psi
@7.6 bar, 0.92 CFM
@110 psi
@ 4.2 bar, 0.29 CFM
@ 60 psi |
Meets API/MDS
Sciex Purity Needs |
• Plug & use system
• Mobile
• Quite in operation
• Reduced vibration
• Fits under Laboratory bench |
| |
|
|
|
|