Onsite Generating Solutions

LC/MS/MS Nitrogen Generators
from PEAK Scientific Instruments

 

Above: PEAK Scientific Instruments Nitrogen for LC/MS/MS-N2

 

Functional Description

For LC/MS/MS-N2 high purity, clean, phthalates free, dry nitrogen gas is required to run 24 hours a day, if necessary, and give trouble free operation. The range available is extensive, including systems with built in air compressor, wall mountable lab units and multiple LC/MS/MS-N2 gas systems. Contact us with your requirements and analyser type and you will be surprised by our knowledge of your application by completing the Contact Form or email to info@onsitegenerating.com

Key Benefits:

• Designed to suit your analyser
• Built in air compressor optional
• Compact, quiet operation
• Eliminates cylinder or liquid dewar change
• No phthalates

Further information on the complete range of LCMS Nitrogen Generators is available.

Nitrogen Generators for LC/MS/ MS Instruments from PEAK Scientific Instruments
Model Flow Rate @ ATP Outlet Pressure Gas Purity Compressor Features
NM18L 18 L/min ATP 110 - 145 psi 7.6 bar Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Single MS Instruments
• Optional Oxygen Analyser With Alarm
• Wall Mountable
NM18LA 18 L/min ATP 110 - 145 psi 7.6 bar Meets Purity Requirements
Of LC/MS/MS Instrument
Integral - Oil Less • Designed For Single MS Instruments
• Optional Oxygen Analyser With Alarm
• Wall Mountable
NM30LA 30 L/min ATP 100 psi 7 bar Meets Purity Requirements
Of LC/MS/MS Instrument
Integral - Oil Less • Designed For Multiple MS Instruments
• Plug & Use System
• Wall Mountable
NM30L 30 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple MS Instruments
• Wall Mountable
• Plug & Use System
NM60L 60 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM120L 120 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM180L 180 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM240L 240 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM300L 300 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM360L 360 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
NM420L 420 L/min ATP Input Independent Meets Purity Requirements
Of LC/MS/MS Instrument
No - Connects To In House Air • Designed For Multiple LC/MS Instruments
N110DR
30 L/min
120 psi / 6.89
bar
Meets Purity
Requirements
Of LC/MS/MS
Instrument
Integral - Oil Less
Dual Redundant
Air
• Designed For Multiple MS
Instruments
• Improved Reliability
• Mobile
A120DR 80 L/min 120 psi / 8.27
bar
Meets Purity
Requirements
Of LC/MS/MS
Instrument
Integral - Oil Less
Dual Redundant
Air
• Designed For Multiple MS
Instruments
• Improved Reliability
• Mobile
A320DR 80 L/min 120 psi / 8.27
bar
Meets Purity
Requirements
Of LC/MS/MS
Instrument
Integral - Oil Less
Dual Redundant
Air
• Designed For Multiple MS
Instruments
• Improved Reliability
• Mobile
NM32LA 32 L/min
ATP
100 psi / 6.9
bar
Meets Purity
Requirements
Of LC/MS/MS
Instrument
Integral - Oil Less • Designed For Multiple MS
Instruments
• Self Diagnostic for trouble free
operation
• Plug & Use System

info kit Customer Information Kit for LC/MS/MS Analysers

 

Many Instruments and Applications such as: GC , LC, Autosamplers, LCMS, Evaporation, AA, CO2 Analysers, Emission Analysers, FT-IR, Lasers, NMR, Ozone Analysers, Rheometers, Robotic Systems, Thermal Analysers, Stack Gas Sampler, Total Hydrocarbon Analyser, Total Organic Carbon Analyser, Fumehoods, Carbon Analysers, Purging, Sparging, Pneumatics and more...all need pure, clean & dry gas and this can be provided by gas generators.

The gas generator range includes:Air Nitrogen GeneratorsCompressed Air Units for API LC/MS/MS & LC/MS/MSELSD Nitrogen GeneratorsHydrogenNitrogenNitrogen Generating PlantsNitrogen for LC/MS/MSGas Stations - Nitrogen Generators for API LC/MS/MSNitrogen for LCMS Complete RangeZero AirCalibration GasPurge GasAPI LC/MS/MS Nitrogen Generator RangeTOC GasAir Dryers and PurifiersAutomatic Switch OverAir NitrogenGas Leak Detection

Additional References: Customer Information Kits for LC/MS/MS AnalysersCustomer Information Kits for API LC/MS/MS AnalysersTechnical Articles - GC ApplicationsTrouble Shooting Guides for GC ApplicationIndustrial Gas Generator Application SummaryLaboratory Gas Generator Application Summary